Buy W3G800-CU25-80 AC axial fan by EBM PAPST Find best pricing, stock from factory direct or authorized sources. Immediate delivery, traceability, 1-yr warranty.
Part Number:
W3G710-GU21-91Order(MOQ):
1Payment:
T/T wire transfer , Western UnionProduct Origin:
USAColor:
NewShipping Port:
HK Shenzhen Shanghai GuangzhouLead Time:
3 days (if in stock)Weight | 47 kg |
---|---|
Motor size | 150 |
Size | 710 mm |
Rotor surface | Painted black |
Electronics housing material | Die-cast aluminum, painted black |
Blade material | Sheet aluminum insert, sprayed with PP plastic |
Fan housing material | Sheet steel, galvanized and coated with black plastic (RAL 9005) |
Guard grille material | Steel, coated with black plastic (RAL 9005) |
Number of blades | 5 |
Blade pitch | 0° |
Airflow direction | V |
Direction of rotation | Clockwise, viewed toward rotor |
Degree of protection | IP44 |
Insulation class | "F" |
Ambient temperature note | Occasional start-up at temperatures between -40°C and -25°C is permitted. For continuous operation at ambient temperatures below -25°C (such as refrigeration applications), use must be made of a fan design with special low-temperature bearings. |
Moisture (F) / Environmental (H) protection class | H2 |
Max. permitted ambient temp. for motor (transport/storage) | +80 °C |
Min. permitted ambient temp. for motor (transport/storage) | -40 / -55 °C |
Installation position | Shaft horizontal with cable exit ±45° or rotor at bottom; rotor at top not permissible |
Condensation drainage holes | On rotor side |
Mode | S1 |
Motor bearing | Ball bearing |
Technical features | - Output 10 VDC, max. 10 mA - Output 20 VDC, max. 50 mA - Output for slave 0-10 V - Operation and alarm display - Input for sensor 0-10 V or 4-20 mA - External 24 V input (parameter setting) - External release input - Alarm relay - Integrated PID controller - Motor current limitation - PFC, passive - RS-485 MODBUS-RTU - Soft start - Control input 0-10 VDC / PWM - Temperature derating - Thermal overload protection for electronics/motor - Line undervoltage / phase failure detection |
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system) | <= 3,5 mA |
Electrical hookup | Terminal box |
Motor protection | Reverse polarity and locked-rotor protection |
Protection class | I (with customer connection of protective earth) |
Conformity with standards | EN 14986; EN 60079-0; EN 60079-1; EN 60079-7; EN 60079-11; EN 61800-5-1 / CE |
Approval | EAC / II 2G |